15 W. Main St. Pensacola, FL 32502 tel 850.332-7900 fax 850-332-7904
*.agd files are created in ActiLife immediately when data from a GT1M, GT3X, ActiTrainer, or ASM device is downloaded
through the “Devices” tab. These *.agd files typically contain post-filtered and accumulated data as this is the only type
of data that ActiLife can properly handle. The rows in the database represent whole-number epoch summations (1s, 5s,
10s, 30s, 60s, etc.). However, at the time of this writing all GT1M, GT3X, ActiTrainer, and ASM products that have been
initialized to collect raw data (12Hz or 30Hz) will produce an *.agd file on download. Although the file cannot be
processed in ActiLife, the *.agd format can be exported to *.csv or *.dat through ActiLife’s import/export tool or AGD
viewer tool, both accessible from the File menu.
GT3X+ devices produce a *.gt3x file on download (see
*.gt3x File Format). In order to process in ActiLife, the file must
be exported to *.agd format. This can be done at the time of download by checking “Create AGD File” from the
download dialog box or by using ActiLife’s built-in import/export tool available from the File menu.
*.agd Data Table Format
The data table in the *agd database consist of the following parameters. Their calculations are explained.
dataTimeStampa measure of total Ticks. A single tick represents one hundred nanoseconds or one ten-millionth of a
second. There are 10,000 ticks in a millisecond. The value of this property represents the number of 100-nanosecond
intervals that have elapsed since 12:00:00 midnight, January 1, 0001. More information available at
http://msdn.microsoft.com/en-us/library/system.datetime.ticks.aspx
axis 1Post filtered and accumulated per-epoch vertical activity data
axis 2 (optional) Post filtered and accumulated per-epoch horizontal activity data
axis 3 (optional) Post filtered and accumulated per-epoch perpendicular activity data
steps (optional) Total steps per epoch
hr (optional) Heart beats-per-epoch. This data is only gathered by ActiTrainer devices when those devices are
initialized to collect heart rate data AND when the Polar® Heart Monitor (wireless heart strap) is worn by the user.
Lux (optional) Ambient light sampled once per second (on GT3X+ and ASM devices only) and averaged over the length
of the selected epoch. (e.g., for 60s epochs, this would be the light values summed once per second and divided by 60).
Inclinometer (optional) Device orientation information. This is calculated by sampling the angle of the device over the
entire length of the epoch (30 times per second) and selecting the predominant angle; i.e, the angle “range” that
appeared the majority of the time over the epoch. For details about inclinometer functionality, see the
Inclinometer
Whitepaper.
*.dat File Format
Older versions of ActiLife produced *.dat files when downloading data from devices. These files consist of ten (10) lines
of header data (meta information about the content) followed by epoch accumulated/filtered data. This “DAT” file
Zobrazit stránku 86